About the depression of the ground surface near the construction site of the Tokyo outer ring road (Kan-etsu-Tomei) [9th report]
- Corporate Top
- Press Room
- Press Release Kanto Regional Head Office
- About the depression of the ground surface near the construction site of the Tokyo outer ring road (Kan-etsu-Tomei) [9th report]
November 22, 2020
East Nippon Expressway Co., Ltd. Kanto Regional Head Office
Regarding the ground surface depression that occurred near the construction site of the Tokyo Outer Ring Road (Kan-etsu-Tomei) main line tunnel (southbound), a new underground cavity was confirmed in the ground survey around the depression.
1. 1. place
Near 2-chome, Higashi Tsutsujigaoka, Chofu-shi, Tokyo
2. Cavity situation
The estimated size of the cavity is about 4m deep from the ground surface, about 3m wide x about 27m long, and about 4m thick.
( Attachment [PDF: 563KB] reference)
3. 3. Future response
With safety and security as our top priority, we explain this event to neighboring residents and take necessary measures.
In addition, experts have commented that due to the condition and size of the cavity, it does not immediately cause deformation on the ground surface and does not require urgent action, but it is desirable to fill the cavity early. ..
In response to this, we will take the following measures for the cavities confirmed this time.
-Promptly carry out filling work to the confirmed cavity.
・ We will continue to constantly observe the displacement of the ground surface. No abnormalities have been confirmed at this time.
We will continue to investigate the cause and the causal relationship with the construction, including the cavity confirmed this time.